Quality & Norms

Quality & Norms

Raw Material are produced from qualified sources. The following tests on aggregates are preformed to guarantee consistency of concerte mixed.

  • Sieve anaylsis - ASTM C136, performed daily.
  • Absorpition and specific gravity - ASTM C127 and C128, performed once per week
  • The Moisture content of aggregates is measured by the mixer controller in order to make proper adjustments in mixing water automatically.

No Type of Test Frequency Standard Ref.
1 Visual Inspection Each pipe QC team
2 Dimensional control Each pipe DIN 40322 Sec 8.2
3 Circularity Each pipe DIN 40322 Sec 8.2
4 Crushing loads 1 pipe / 2 weeks DIN 40322 Sec 8.31
5 Cube compressive strengths 3 cubes / week DIN 4032 Sec 8.3.3.1
6 Water/cement ratio Every mix DIN 1048 Part 1
7 Water tightness 1 pipe /  week DIN 4032 Sec 8.4.1
8 Water absorption 1 pipe /  week DIN 4032 Sec 8.4.2
9 Air Test 1 pipe /  week BS 8005 Sec 5.13.3
10 Vacuum Test Each pipe ASTM C1214

 

All tests performed by Beton Bekaa personnel are supervised by an external qualified materials engineering consultant.


External Load Crushing Strength Test

Vacuum Test

Hydrostatic or Air Test